Electrical · Free online course
Protection Relays: Settings, Testing and Commissioning
Protection relays from the CT to the commissioning record: faults and zones, CTs and VTs, fuses and IDMT curves, overcurrent and earth-fault grading by hand, transformer differential and REF, distance, motor and generator protection, numerical relays and COMTRADE, then primary and secondary injection, trip-circuit and stability tests, and maintenance.
- 13 modules
- 17h 13m of video
- Intermediate
- English
- ₹0, free
- Lab practice in your browser

₹0Free for good
Worth ₹9,999 by length and depth against classroom training. It has always been free; that is not a former price.
No card. Checkout takes a minute and gives you a receipt.
Certificate ₹599, optional. The course is free either way.
Overview
About Protection Relays: Settings, Testing and Commissioning
Understand protection relays from CTs to commissioning: set and grade them by hand, then plan injection and stability tests.
Protection Relays: Settings, Testing and Commissioning is a free, self-paced online course from EDWartens for electrical, testing and commissioning engineers and technicians who set and test protection relays. It has 13 modules and 17h 13m of video lessons, with written notes, a practice task per module, a practical project and a final assessment of 15 questions (pass mark 60%). Learning costs nothing and needs only a free account. The optional EDWartens Certificate of Completion, verifiable by code, is a one-off ₹599 inclusive of GST for learners in India; it is not a vendor credential. Updated 1 November 2026.
Who it is for: Electrical, testing and commissioning engineers and technicians who set and test protection relays
This course includes
- 17h 13m of video lessons
- 13 modules with written notes and diagrams
- One final assessment: 15 questions, pass mark 60%
- Ask-an-engineer support from practising engineers
- Lifetime access, the course does not expire
- Optional verifiable certificate when you finish
- Step 1 of 3
Learn the 13 modules
17h 13m of video lessons, written notes and a practice task per module, at your own pace.
- Step 2 of 3
Pass the final assessment
15 questions drawn from every module, pass mark 60%, 3 attempts.
- Step 3 of 3
Take the certificate, if you want it
Optional, paid once, only if you choose it. The course stays free either way.
See the certificate and its price
A look inside



From the lessons

Why protect: faults, zones, selectivity and speed
by IIT Roorkee July 2018

Fuses, MCCB trip units and IDMT curves
by TestGuy

Transformer differential and restricted earth fault
by Romero Engineering Company

Motor and generator protection
by IIT Roorkee July 2018

Primary injection and CT tests: ratio, polarity and magnetising curve
by OMICRONenergy

Trip-circuit checks, stability tests and commissioning records
by Electrical Passionate
Lesson frames belong to the creators named in the Credits and are shown from YouTube.
What you learn
What you will be able to do
By the end you will be able to:
- Check a CT's class and knee point for its duty
- Set and grade overcurrent and earth-fault relays by hand
- Set transformer differential and distance protection
- Read event reports and COMTRADE records
- Plan primary and secondary injection tests and prove trip circuits
How it works
How this course works
Watch the lessons
Short video lessons, one module at a time, at your own pace.
Read the notes
Open the Reading tab for the written notes and diagrams of the module.
Practise in the 3D labOptional
Try the module in the free 3D lab, in your browser.
Check yourself
Answer the questions to see what stuck before you move on.
Final assessment
Pass the final once you have been through the modules.
Certificate, if you want oneOptional
Optional, with a page anyone can use to verify it.
Syllabus
Course content, module by module
In order, at whatever pace suits you. Each module ends with a practice task that builds on the last.
- Modules
- 13
- Video lessons
- 64
- Of video
- 17h 13m
- Final questions
- 15
- 01
Why protect: faults, zones, selectivity and speed, with lab practice:
2 lessons · 40m - 02
CTs and VTs: ratio, class, knee point, polarity and saturation
4 lessons · 1h 38m - 03
Fuses, MCCB trip units and IDMT curves, with lab practice:
4 lessons · 1h 20m - 04
Overcurrent and earth-fault settings and grading by hand, with lab practice:
6 lessons · 2h 7m - 05
Transformer differential and restricted earth fault
4 lessons · 1h 24m - 06
Distance protection for lines: zones and reach
5 lessons · 1h 42m - 07
Motor and generator protection
7 lessons · 2h 3m - 08
Numerical relays: settings files, disturbance records and COMTRADE
6 lessons · 1h 29m Final assessment · 15 questions, pass mark 60%
3D lab
Practise in the 3D lab
Work out a fault level and set an IDMT relay so it discriminates with the breaker below it, the heart of overcurrent protection.
- Read the single-line diagramSubstation and MCC labOpen in the lab (opens in a new tab): Read the single-line diagram
- Fault level and breaker checkSubstation and MCC labOpen in the lab (opens in a new tab): Fault level and breaker check
- Grade the incomer relaySubstation and MCC labOpen in the lab (opens in a new tab): Grade the incomer relay
Optional. Skip it whenever you like: it never blocks your progress or your certificate.
Project
The course project
Optional practice that ends in the kind of job the course prepares you for, with the documents that go with it.
About 11 hours
Overcurrent grading and secondary-injection test plan for a three-level 11 kV and 415 V radial network
Grade the phase overcurrent relays on a three-level 11 kV and 415 V radial network from given fault levels. Write the relay setting sheet and the secondary-injection test plan with expected trip times and tolerances. The sample pack shows each document for a chemical plant's main substation near Johannesburg.
- 5documents in the pack
- 7steps to follow
- Laboptional: in the 3D lab
- 5things to hand in
- 11 hof work, at your pace
Do it in the lab: 4 steps.
Sample document pack, 5 documents, filled in for the scenario
- Single lineSingle-line description: process block 11 kV and 415 V supply
- ReportOvercurrent grading study: R3, R2 and R1
- RegisterRelay setting sheet: R1, R2 and R3
- SATSecondary-injection test record: R1, R2 and R3
- Commissioning procedureCommissioning checklist: protection for R1, R2 and R3
Read inside the course and download as a workbook. The project is optional practice, marked when you submit it; the certificate needs only the modules and the final assessment.
Tools
Software, hardware and lessons
Software
A spreadsheet (LibreOffice Calc is free) for the grading and test sheets. SEL ACSELERATOR QuickSet to see how settings are entered, and a COMTRADE viewer, are useful but optional. A relay test set is not required: every test is planned and its results worked on paper.
Hardware
None required. Access to a numerical relay and a secondary injection test set at work or college makes the testing modules far more useful.
Who it is for
Intermediate. For electrical engineers, testing and commissioning engineers and technicians, and final-year electrical students. You should know three-phase power, per-unit and basic fault ideas; per-unit and symmetrical components are revised where they are used.
Video lessons by
- Romero Engineering Company
- OMICRONenergy
- NPTEL IIT Kharagpur
- IIT Roorkee July 2018
- Hamada Diab
- Schweitzer Engineering Laboratories (SEL)
- Testing Tech Tips
- Power Globe
- Doble Engineering
- Megger
- TestGuy
- Electrical Passionate
- Circuit Masterclass
Independent creators, credited in full under Credits.
Software you need
What to download, where from, what it costs and how to install it. Every link goes to the maker's own site, never a mirror.
Nothing to install
A spreadsheet is enough for the grading and test sheets. SEL's ACSELERATOR QuickSet (Windows, from selinc.com/products/5030) is useful to see how relay settings are entered, and any COMTRADE viewer opens fault records; neither is required.
Optional
Useful, not needed to finish the course.
- 01Free
LibreOffice
The Document Foundation
- Runs on
- Windows 10 or 11, macOS 11 or newer (Intel or Apple silicon), Linux
- Account
- None needed
- Size
- up to 1.5 GB of disk space on Windows
LibreOffice is free, open-source software under the Mozilla Public License 2.0, for any use including business. Calc is its spreadsheet.
Steps
- 1.Open the LibreOffice download page.
- 2.Check the page has picked your operating system, then select Download.
- 3.Run the installer (administrator rights are needed on Windows).
- 4.Start LibreOffice Calc for spreadsheet work.
- 5.Save as .xlsx if you need to share files with Excel users.
- Choose the latest main version unless your organisation asks for the older, more conservative release.
Official download pagelibreoffice.org
Checked against each maker's own page on 27 September 2026. Trial lengths and editions change; the maker's page is the final word.
What you walk away with
Your certificate for Protection Relays: Settings, Testing and Commissioning
Finish the course, pass the final, and this is the document with your name on it.

Verifiable by anyone
Adds to LinkedIn in one click
QR code on the certificate
Names what you can do
A permanent link
Earned, not attended
Learning is free. The certificate is optional.
Add it now and pay only when you have finished the course, or come back for it later. One-off, US$28.99, with a receipt.
Issued by Wartens Ltd (England and Wales, company no. 15262249) through the EDWartens training portal, as a Certificate of Completion for this self-paced course. Sold in India by Wartens Automation Private Limited. It is not a vendor certification, a university award or a CPD-accredited activity, and it does not certify competence on live equipment. Delivered electronically; see the refund policy.
Practise what you learn in the free 3D lab
Technical work is judged on what you can do: wiring, commissioning, finding a fault. Doing a task yourself teaches more than watching it a second time, and a lab lets you try it safely before you meet real equipment. It does not replace working on real hardware.
- Practise safely, so a mistake costs nothing.
- The lab checks your work like a site test, so you know when it is right.
- Free, in your browser, with nothing to install.
Why learn with EDWartens
What you get with this course.
- Free from the first lesson to the final assessment.
- Practice in a free 3D lab in your browser, with nothing to install.
- Video lessons with written notes and a project.
- An optional certificate that anyone can verify online.
FAQ
Common questions
Who is this protection relay course for?
Electrical engineers, testing and commissioning engineers and technicians, utility and plant electrical staff, and final-year electrical students who need to set and test protection relays. It suits people moving into testing and commissioning work.
What do I need to know before starting?
Three-phase power, per-unit quantities and the basic idea of a short circuit. Symmetrical components and per-unit are revised where they are used. No relay or test set experience is needed.
Do I need a relay test set or software?
No. Every setting is calculated by hand or in a free spreadsheet, and every test is planned and its results worked on paper. SEL ACSELERATOR QuickSet and a COMTRADE viewer help you see real settings files and records, and access to a test set at work makes the testing modules more practical.
Which standards does it follow?
The IDMT curves are the IEC 60255 inverse curves and the IEEE C37.112 curves used by numerical relays, records use the COMTRADE format, and maintenance intervals use NERC PRC-005 as a worked example. The course paraphrases these standards; it does not reproduce them, and you should check the edition your plant uses.
How is this different from the ETAP course?
The ETAP Power System Analysis course runs coordination studies in software. This course does the grading by hand and then proves the settings with primary and secondary injection, the way a commissioning engineer works. Taking both is a good combination.
How long does the Protection Relays: Settings, Testing and Commissioning course take?
About 23 hours of video lessons, notes and practice, taken at your own pace; the videos alone are about 17 hours. The optional project takes about 10 hours more.
Is the course free, and what certificate do I get?
Every module, the notes, the project and the final assessment are free. If you pass the 15-question final at 60 percent you can get an EDWartens Certificate of Completion, with a number anyone can verify on our site. It is a certificate of completion, not a licence or a vendor qualification from SEL, OMICRON or any test-set maker.
What jobs does it lead to?
It builds the knowledge used in protection testing and commissioning work with contractors, utilities and EPC firms, in substation maintenance, and in protection settings work for consultancies. Employers will still expect hands-on time with test sets, which this course prepares you to use well.
Do I have to use the lab?
No. The lab is optional practice. You can skip it whenever you like, and it never blocks your progress, the final assessment or your certificate.
Is the lab free?
Yes. Every lab level for this course opens in your browser, free, with nothing to install.
Is the Protection Relays: Settings, Testing and Commissioning course free in India, and what does the certificate cost?
Yes. Learning costs ₹0 in India: every module, the written notes, the practice tasks and the final assessment, with no card and no trial period. The only paid item is the optional EDWartens Certificate of Completion, ₹599 including GST for this intermediate course, paid in rupees through Razorpay, and only if you want it after passing the final assessment.
What topics does the Protection Relays: Settings, Testing and Commissioning course cover, module by module?
The Protection Relays: Settings, Testing and Commissioning course has 13 modules. It opens with "Why protect: faults, zones, selectivity and speed", goes through "CTs and VTs: ratio, class, knee point, polarity and saturation", "Transformer differential and restricted earth fault", "Primary injection and CT tests: ratio, polarity and magnetising curve" and "Relay maintenance, test intervals and faults commonly found" and ends with "Final Assessment". The full list with minutes is under "What you learn" on this page.
What can I do after the Protection Relays: Settings, Testing and Commissioning course?
After the Protection Relays: Settings, Testing and Commissioning course: Calculate fault currents from fault levels and draw overlapping zones of protection; Check a protection CT's class and knee point against the voltage its duty needs; Calculate IEC and IEEE inverse-time trip times and read fuse and LSIG trip-unit curves. These are the practical outcomes the course is written around, and the final assessment of 15 questions checks them.
What software and hardware do I need for the Protection Relays: Settings, Testing and Commissioning course, and does it cost anything?
For the Protection Relays: Settings, Testing and Commissioning course, software: A spreadsheet (LibreOffice Calc is free) for the grading and test sheets. SEL ACSELERATOR QuickSet to see how settings are entered, and a COMTRADE viewer, are useful but optional. A relay test set is not required: every test is planned and its results worked on paper. Hardware: none required. Access to a numerical relay and a secondary injection test set at work or college makes the testing modules far more useful. The course itself is free.
Is the Protection Relays: Settings, Testing and Commissioning course suitable for me, and what level is it?
Protection Relays: Settings, Testing and Commissioning is rated intermediate. Intermediate. For electrical engineers, testing and commissioning engineers and technicians, and final-year electrical students. You should know three-phase power, per-unit and basic fault ideas; per-unit and symmetrical components are revised where they are used. It is written for electrical, testing and commissioning engineers and technicians who set and test protection relays, and has 17h 13m of video lessons at your own pace.
Which jobs use the skills from the Protection Relays: Settings, Testing and Commissioning course?
Skills from the Protection Relays: Settings, Testing and Commissioning course (for example: calculate fault currents from fault levels and draw overlapping zones of protection) are used in protection and commissioning engineer work. The course gives you practical evidence of the skill; it does not promise a job, and employers decide on experience and interview.
All course factsHide course facts
- Price
- ₹0, free for good. No trial, no card. Comparable classroom training of this length costs about ₹9,999.
- Who it is for
- Electrical, testing and commissioning engineers and technicians who set and test protection relays
- Format
- 13 self-paced modules, 17h 13m of video, written notes, a practice task per module and one final assessment.
- Level
- Intermediate. Intermediate. For electrical engineers, testing and commissioning engineers and technicians, and final-year electrical students. You should know three-phase power, per-unit and basic fault ideas; per-unit and symmetrical components are revised where they are used.
- Brand
- Vendor-neutral
- Software
- A spreadsheet (LibreOffice Calc is free) for the grading and test sheets. SEL ACSELERATOR QuickSet to see how settings are entered, and a COMTRADE viewer, are useful but optional. A relay test set is not required: every test is planned and its results worked on paper.
- Hardware
- None required. Access to a numerical relay and a secondary injection test set at work or college makes the testing modules far more useful.
- Certificate
- Optional EDWartens Certificate of Completion, ₹599 inclusive of GST for learners in India, verifiable by code. Not a vendor credential.
- Video lessons by
- Romero Engineering Company, OMICRONenergy, NPTEL IIT Kharagpur, IIT Roorkee July 2018, Hamada Diab, Schweitzer Engineering Laboratories (SEL), Testing Tech Tips, Power Globe, Doble Engineering, Megger, TestGuy, Electrical Passionate, Circuit Masterclass (independent creators, credited below)
- Language
- English
- Last updated
- 1 November 2026
Pairs well with
Electrical · FreeETAP Power System Analysis: Load Flow, Short Circuit, Protection, Arc Flash and Stability
PLC programming · FreeSiemens TIA Portal
PLC programming · FreeSiemens TIA Portal in Three Hours
PLC programming · FreeTIA Portal: Build a MachineMore free courses: Free electrical design and control panel courses · Free power system and ETAP courses
Classroom course, Bangalore
Industrial automation course in Bangalore
The Automation Engineer Program (AEP) covers PLC, SCADA, HMI, drives, measuring instruments, PID basics and control panel design, taught in person at our Electronic City centre.
Credits
Who made the video lessons
The video lessons in this course were created by the people below, not by EDWartens. Every lesson streams from its creator's own YouTube channel; EDWartens neither hosts nor sells that footage, and the creators are not affiliated with EDWartens and do not endorse this course. What EDWartens wrote is the study plan, the notes, the practice tasks and the assessments.
- Romero Engineering Companythe Power System Protection and Control lessons: CT basics and saturation, calculating SEL and IEEE inverse-time trip times, overcurrent basics, neutral overcurrent of transformers, directional control, transformer differential TAP and compensation settings, harmonic restraint and blocking, restricted earth fault, distance protection, infeed, load encroachment, POTT, motor differential, trip event analysis, one-line and three-line drawings, breaker failure protection and symmetrical components
- OMICRONenergythe Test Universe lessons (QuickCMC, Ramping, Overcurrent, State Sequencer, Advanced Differential, Advanced Distance, Annunciation Checker and XRIO test automation) and the CT Analyzer lessons on protection CT testing, multi-ratio CTs and remanence (playlist https://www.youtube.com/playlist?list=PLzmbZeI1bhu-bwtPfgxqAFE-LyK4DzX0h)
- NPTEL IIT KharagpurNPTEL Power System Protection lectures on current transformers, capacitor voltage transformers, overcurrent relay characteristics, overcurrent coordination, relay coordination with fuses and the numerical relaying concept
- IIT Roorkee July 2018NPTEL Power System Protection and Switchgear lectures on the fundamentals of protective relaying, current-based relaying, distance protection of lines, transformer protection, induction motor protection, and testing, commissioning and maintenance of relays
- Hamada Diabthe Generator Protection Training Series (basics and earthing, 87G differential, reverse power, loss of field, thermal overload) and the Test Universe overcurrent module lesson on a Siemens 7SJ85
- Schweitzer Engineering Laboratories (SEL)the AcSELerator QuickSet Device Manager overview, and setting SEL-751 overcurrent and time-overcurrent protection (https://www.youtube.com/watch?v=EtdRdL7Q1is)
- Testing Tech Tipsdownloading and installing settings on SEL relays with AcSELerator QuickSet
- Power Globedisturbance recorder analysis and the COMTRADE standard, and NERC PRC-005 protection system maintenance (https://www.youtube.com/watch?v=ciygSshMbr8)
- Doble Engineeringperforming a current transformer excitation test
- Meggerperforming a manual timing test on a protective relay
- TestGuycircuit breaker electronic trip units explained
- Electrical Passionatepre-close and post-close trip-circuit supervision, and calculating currents for a transformer REF stability test (https://www.youtube.com/watch?v=64P0_NgGq9w)
- Circuit Masterclassprotection zones and why they overlap
If you are one of these creators and would like a lesson removed or credited differently, write to info@edwartens.co.in.
